Send Message
China Healthlead Air Purifier manufacturer

Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C

Product Details:
Place of Origin: Guangdong, China
Brand Name: Healthlead
Certification: CQC, CE(LVD), CE(EMC), ETL, CARB, CB, ROHS, GS, PSE
Model Number: EPI131C
Payment & Shipping Terms:
Minimum Order Quantity: 2000 Pieces
Price: Negotiable
Packaging Details: EPI131C <br>1 piece product in one giftbox package, and 2 piece giftbox in a carton.
Delivery Time: 35-40 Days
Payment Terms: L/C, T/T
Supply Ability: 1500piece/day

Detail Information

Digital Display: Particle Sensor, PM2.5 Digital Display As Optional App-Controlled: YES
Featured Function: Auto Mode And Sleep Mode Function Air Flow: 200M3/h
Motor: DC Motor Filter Replacement: Filter Change Reminder
Auto Mode: The Wind Speeds Are Graded And Change Automatically According To PM2.5 Values Button Display: White LED Light Display
Product Dimension(mm): 210*210*310 Smoke CADR(CFM): 70
Negative Ion Concentration: 10 X 106 Ions/cm3 Input Power Supply: 230VAC ±10% 50Hz
Input Power: 28W Rated Current: 130mA
Warranty: 1 Year,
High Light:

indoor desktop HEPA air purifier

,

desktop HEPA air purifier 200M3/h

,

EMC HEPA Air Purifier

Product Description

EPI131C Negative ion to remove dust function, low power consumption indoor desktop HEPA air purifier

 

Product features and functions 1. Touch button control.
2. Filter timing function.
3. Sleep mode function.
4. PM2.5 sensor function.
5. 3-speed wind speed function.
6. Negative ion function

 

Technical specifications 1: Meets low power consumption requirements (standby less than 0.5W).
2: Input power 230VAC ±10% 50Hz.
3: Input power 28W; rated current: 130mA
4: CADR (particles): 120m3/h - 10%.
5: Negative ion concentration: 10 x 106 ions/cm3
6: Ozone concentration: < 0.05ppm.
7: Noise: ≤ 55dB(A) sound pressure level.
8: Low voltage start: rated voltage -10%
9: Speed definition
Gear sleep 1 2 3 standby
Rotational speed (RPM/MIN) 550±150 550±150 1000±250 2300±300 N/A
10: Rated power(W)
Gear sleep 1 2 3 standby
Power of the whole machine 3±2W 3±2W 9.5±4W 23±5W N/A
11: Working voltage (V/Hz):AC120/230V
12: rated power: 21W
13: Smoke CADR(CFM):70
14: Suggested room size(㎡):14
15: Product dimension(mm):210*210*310
16: Unit weight(kg):1.5

 

Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 0

Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 1
Specification
Packing & Delivery
 
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 3
Company Profie
Healthlead is one major leading professional air purifier, mini dehumidifier and environmental protection material developing, manufacturing and marketing high- tech enterprise, Registered capital is US$10 million and factory coverage is 42,000 sq meters . Owing with professional and innovating product development capability, Healthlead becomes key OEM & ODM supplier of mostly im porter and distributor in North America, China and Europe etc. Healthlead factory quality system was approved by ISO9001, ISO1400 1, BSCI, and authorized by US JCS, Whirlpool, The Home Depot, TTI, Germguardian, Homedics, Bissell, Europe ALDI, LIDL, B&Q, Auchan, China Suning, Huawei, Haier, Konka, TCL, Airmate, Chigao, Royalstar, Westinghouse for factory audit. The factory owns in-house safety approval lab to performance and relia bility test to meet different customer’s product need. Daily production capability is 20,000 units to 25,000 units in order to on-time delivery.
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 5
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 7
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 9
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 11
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 13
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 15
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 17
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 19
Negative Ion To Remove Dust Indoor Desktop HEPA Air Purifier 200M3/H EPI131C 21
Our Advantages
20 years experience in airpurifier OEM & ODM service. Approved by ISO9001,2015, ISO14001. ETL, GS, CE safety laboratories authorized by Intertek. More than 30 R& D engineers. Six-stage of air purification system combined pre-filter, Hepa filter, active carbon filter, Nona-silver antibacterial, ionizer, photocatalyst filter, UV.
FAQ
1.What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room. Clean Air Delivery Rate From air cleaner to air cleaner, compare the CADR numbers.
First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.

2. What is CFM and CMH of CADR?
1 CFM=1.71CMH

3. TROUBLESHOOTING GUIDE
A. Unit shuts off unexpectedly or does not operate.
Check that the unit is plugged into a working electrical outlet.
Check that the motor protector is triggered.
Check that the filter is in the unit and locked.
Check that the front panel is latched firmly in place.
B. No air circulating from unit
Unplug unit. Check filter. Replace filter if necessary.
C. Increase in noise level
Make sure the filter is clean. Replace if necessary.
D. Odors and smoke are not removed.
Clean or replace the filter if it appears to be heavily soiled.
E. The discharged air has an aroma or odor
Check to see if the filter is heavily soiled. Replace the filter. Turn off the Ionizer
F. Air quality indicator constantly shows poor air quality
Wipe the lens with a clean cloth or vacuum to remove any dust that has settled on the sensor.
G. Filter change indicator flicks
Need to manual reset by long pressing filter change icon for 5 seconds, then release after heard the buzzer
H. The unit can not power on without buzzer and power icon lighting
Replace with new power PCBA
I. The unit can power on with power icon lighting, but speed can not be set.
Replace with new control PCBA
J. The unit can power on but some displays show defective
Replace with new control PCBA
K. The unit’s PM 2.5 digital value shows different from ambient environment within 30% tolerance.
Comply with particle sensor spec.
L. The unit’s PM 2.5 digital value shows different from ambient environment beyond 30% tolerance.
Replace with new particle sensor.
M. The unit’s VOC digital value shows different from ambient environment.
Replace with new VOC sensor.
N. The unit is power on with all the buttons normal work including power icon lighting, but no air outtake comes.
Remove filter plastic bag and re-install filter, then re-start.
O. The unit is power on with all the buttons normal work including power icon lighting, but no air outtake comes.
Replace with new motor
P. No ion comes out
Disassembly the unit, and re-insert ionizer module wire socket
Q. There has odor coming out from outtake grill
Replace with new filter
R. The unit is power on but some display missed
Replace with new display board.
S. Wifi can not be connected
Reset the route as 2.4G
T. Wifi can not be connected
Replace with new Wifi module
U. Power button is invalid after turn on with heard buzzer
Replace with new control panel or magnetic switch board